Browsing by Author "KC, Ashish"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Effect of early versus delayed cord clamping in neonate on heart rate, breathing and oxygen saturation during first 10 minutes of birth - randomized clinical trial(2019-05-30) KC, Ashish; Singhal, Nalini; Gautam, Jageshwor; Rana, Nisha; Andersson, OlaAbstract Background Delayed cord clamping (DCC) after 180 s reduces iron deficiency up to 8 months of infancy compared to babies who received Early Cord Clamping (ECC) at less than 60 s. Experimentally DCC has shown to improve cardio-vascular stability. To evaluate the effect of delayed (≥180 s) group versus early (≤60 s) cord clamping group on peripheral blood oxygenation and heart rate up to 10 min after birth on term and late preterm infants. Methods We conducted a single centred randomized clinical trial in a low risk delivery unit in tertiary Hospital, Nepal. One thousand five hundred ten women, low risk vaginal delivery with foetal heart rate (FHR) ≥ 100 ≤ 160 beats per minute (bpm) and gestational age (≥33 weeks) were enrolled in the study. Participants were randomly assigned to cord clamped ≤60 s of birth and ≥ 180 s. The main outcome measures were oxygen saturation, heart rate from birth to 10 min and time of spontaneous breathing. The oxygen saturation and heart rate, the time of first breath and establishment of regular breathing was analysed using Student t-test to compare groups. We analysed the range of heart rate distributed by different centiles from the time of birth at 30 s intervals until 10 min. Results The oxygen saturation was 18% higher at 1 min, 13% higher at 5 min and 10% higher at 10 min in babies who had cord clamping in delayed group compared to early group (p < 0.001). The heart rate was 9 beats lower at 1 min and3 beats lower at 5 min in delayed group compared to early group (p < 0.001). Time of first breath and regular breathing was established earlier in babies who had cord clamping at 180 s or more. Conclusion Spontaneously breathing babies subjected to DCC have higher oxygen saturation up to 10 min after birth compared to those who have undergone ECC. Spontaneously breathing babies with DCC have lower heart rates compared to ECC until 390 s. Spontaneously breathing babies receiving DCC have early establishment of breathing compared to ECC. Trial registration ISRCTN , 5 April 2016.Item Open Access Neonatal resuscitation: EN-BIRTH multi-country validation study(2021-03-26) KC, Ashish; Peven, Kimberly; Ameen, Shafiqul; Msemo, Georgina; Basnet, Omkar; Ruysen, Harriet; Zaman, Sojib B; Mkony, Martha; Sunny, Avinash K; Rahman, Qazi S; Shabani, Josephine; Bastola, Ram C; Assenga, Evelyne; KC, Naresh P; El Arifeen, Shams; Kija, Edward; Malla, Honey; Kong, Stefanie; Singhal, Nalini; Niermeyer, Susan; Lincetto, Ornella; Day, Louise T; Lawn, Joy EAbstract Background Annually, 14 million newborns require stimulation to initiate breathing at birth and 6 million require bag-mask-ventilation (BMV). Many countries have invested in facility-based neonatal resuscitation equipment and training. However, there is no consistent tracking for neonatal resuscitation coverage. Methods The EN-BIRTH study, in five hospitals in Bangladesh, Nepal, and Tanzania (2017–2018), collected time-stamped data for care around birth, including neonatal resuscitation. Researchers surveyed women and extracted data from routine labour ward registers. To assess accuracy, we compared gold standard observed coverage to survey-reported and register-recorded coverage, using absolute difference, validity ratios, and individual-level validation metrics (sensitivity, specificity, percent agreement). We analysed two resuscitation numerators (stimulation, BMV) and three denominators (live births and fresh stillbirths, non-crying, non-breathing). We also examined timeliness of BMV. Qualitative data were collected from health workers and data collectors regarding barriers and enablers to routine recording of resuscitation. Results Among 22,752 observed births, 5330 (23.4%) babies did not cry and 3860 (17.0%) did not breathe in the first minute after birth. 16.2% (n = 3688) of babies were stimulated and 4.4% (n = 998) received BMV. Survey-report underestimated coverage of stimulation and BMV. Four of five labour ward registers captured resuscitation numerators. Stimulation had variable accuracy (sensitivity 7.5–40.8%, specificity 66.8–99.5%), BMV accuracy was higher (sensitivity 12.4–48.4%, specificity > 93%), with small absolute differences between observed and recorded BMV. Accuracy did not vary by denominator option. < 1% of BMV was initiated within 1 min of birth. Enablers to register recording included training and data use while barriers included register design, documentation burden, and time pressure. Conclusions Population-based surveys are unlikely to be useful for measuring resuscitation coverage given low validity of exit-survey report. Routine labour ward registers have potential to accurately capture BMV as the numerator. Measuring the true denominator for clinical need is complex; newborns may require BMV if breathing ineffectively or experiencing apnoea after initial drying/stimulation or subsequently at any time. Further denominator research is required to evaluate non-crying as a potential alternative in the context of respectful care. Measuring quality gaps, notably timely provision of resuscitation, is crucial for programme improvement and impact, but unlikely to be feasible in routine systems, requiring audits and special studies.