Binocular Sensitivity and Specificity of Screening Tests in Prospective Studies of Paired Organs
atmire.migration.oldid | 705 | |
dc.contributor.advisor | de Leon, Alexander | |
dc.contributor.author | Perera, Singappuli | |
dc.date.accessioned | 2013-01-28T16:00:22Z | |
dc.date.available | 2013-06-15T07:01:47Z | |
dc.date.issued | 2013-01-28 | |
dc.date.submitted | 2013 | en |
dc.description.abstract | Diagnostic and screening studies in ophthalmology frequently involve binocular data where pairs of eyes are evaluated, through some diagnostic procedure, for the presence of certain diseases or pathologies. It is usually sufficient in practice that at least one eye is positively diagnosed for the patient to be sent for further and more extensive eye examination. More relevant diagnostic accuracy measures in these cases are therefore the probability of at least one correct positive diagnosis in patients with one or both eyes truly diseased and the probability of two correct negative diagnoses for patients with both eyes truly un-diseased. The former is analogous to sensitivity and the latter to specificity. Predictive values may be similarly re-defined. The thesis proposes these new sensitivity and specificity measures as alternatives to conventional ones for paired binocular binary diagnostic data arising from screening studies with cross-sectional sampling. The measures are defined for flexible models based on copulas and extensions of existing models for correlated binary data. The proposed methodology is illustrated with data from a study on diabetic retinopathy. | en_US |
dc.identifier.citation | Perera, S. (2013). Binocular Sensitivity and Specificity of Screening Tests in Prospective Studies of Paired Organs (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25120 | en_US |
dc.identifier.doi | http://dx.doi.org/10.11575/PRISM/25120 | |
dc.identifier.uri | http://hdl.handle.net/11023/517 | |
dc.language.iso | eng | |
dc.publisher.faculty | Graduate Studies | |
dc.publisher.institution | University of Calgary | en |
dc.publisher.place | Calgary | en |
dc.rights | University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission. | |
dc.subject | Biostatistics | |
dc.subject | Ophthalmology | |
dc.subject | Statistics | |
dc.subject.classification | copulas, ECCM, ophthalmology, retinopathy | en_US |
dc.title | Binocular Sensitivity and Specificity of Screening Tests in Prospective Studies of Paired Organs | |
dc.type | master thesis | |
thesis.degree.discipline | Mathematics and Statistics | |
thesis.degree.grantor | University of Calgary | |
thesis.degree.name | Master of Science (MSc) | |
ucalgary.item.requestcopy | true |