dc.description.abstractThe 2005 National Building Code of Canada (N BCC) requires that buildings be able to resist an earthquake that can occur once every 2500 years (2% chance of exccedance in 50 years). In a project to maintain and conserve the Parliament Buildings of Canada, it was required to assess the buildings in relation to their ability to conform to the requirements of the NBCC. For older buildings like the Parliament Buildings of Canada, the code requires that such buildings be able to resist at least 60% of the forces exerted on it by the 1 in 2500 years earthquake. Therefore, it was necessary to evaluate the caracity of the buildings on Parliament Hill, and the loads that could develop in the buildings in the case of an earthquake of the expected magnitude. In order to calculate the capacity or the buildings, and the forces exerted on them by an earthquake, certain properties of the walls constituting the building should be identified like the elastic modulus and the shear modulus. This thesis focuses on determining these properties for walls representative of the West Block or the ParIiament BuiIdings, the building currently undergoing maintenance. The question was also raised as to what strengthening measures could be implemented if the walls needed such treatment, as it was expected that the unreinforced masonry walIs would not be able to survive such an earthquake. Accordingly, several potential strengthening techniques were assessed during the study. The West Block is constructed from unreinforced stone masonry walls. The walls are multiwythe with an outer face of sandstone, and an inner of limestone, surrounding a rubble core of dressed stones and mortar. Eight wall specimens representative or the walls of the West Block were built with materials similar to those used in the building. The walls were 2.75 111 high , 2 111 wide and 0.54 111 thick. Five potential strengthening techniques were applied in the walls, all being through-the-wall anchorage systems. The walls were tested in different conditions to obtain the properties sought, as well as any other information about the properties of the walls and their behaviour. The walls were tested under eccentric and concentric axial compression, shear, flexure, free vibration, slow and high frequency racking, at which push/pull lateral loading cycles were applied on the walls, and out-of-plane shake tests, where the walls were subjected to scaled earthquake signals on a shake table. The results obtained from the axial , shear and flexure tests were analyzed to obtain the properties sought. The behaviour of such walls was found to be much more complicated than originally thought. Unexpectedly, the plain walls survived all of the tests with little damage, demonstrating their robustness. None or the proposed strengthening techniques were found to make a significant difference to wall behaviour. A large amount of data was obtained from the tests that arc reported here . However, this thesis is focussed on analysing the ยท'static .. results for the information or interest, and assessing the proposed strengthening techniques. The dynamic data arc analysed qualitatively, with the in-depth detailed analysis being left for future research.
dc.format.extentxxi, 214 leaves : ill. ; 30 cm.en
dc.identifier.citationSorour, M. M. (2010). Characterization and repair of historic stone masonry structures (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/3530en_US
dc.identifier.doihttp://dx.doi.org/10.11575/PRISM/3530
dc.identifier.urihttp://hdl.handle.net/1880/104531
dc.language.isoeng
dc.publisher.institutionUniversity of Calgaryen
dc.publisher.placeCalgaryen
dc.rightsUniversity of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
dc.titleCharacterization and repair of historic stone masonry structures
dc.typedoctoral thesis
thesis.degree.disciplineCivil Engineering
thesis.degree.grantorUniversity of Calgary
thesis.degree.nameDoctor of Philosophy (PhD)
ucalgary.item.requestcopytrue
ucalgary.thesis.accessionTheses Collection 58.002:Box 1967 627942810
ucalgary.thesis.notesUARCen
ucalgary.thesis.uarcreleaseyen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_Sorour_2010.pdf
Size:
83.46 MB
Format:
Adobe Portable Document Format
Description:
Thesis
Collections